Overview

This OEM hot surface igniter kit pairs the igniter element (part 1171306) with its matching igniter wiring harness/kit (part 1188370) for ICP Tempstar/Heil gas furnaces. On each call for heat, the furnace control sends voltage to the igniter, which glows white-hot and lights the gas at the burners. The igniter is one of the most failure-prone components in a furnace because the brittle element is heat-cycled hundreds of times per season and is easily cracked by handling or contamination. Including the wiring harness ensures a clean, corrosion-free connection from the control board to the igniter — a frequent secondary failure point. Replacing both together restores reliable, fast ignition and eliminates the no-heat, repeated-retry, and lockout symptoms caused by a cracked element or a chafed, melted harness.

Specifications

Spec Value
OEM Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter Kit
Brand ICP (Tempstar / Heil / Comfortmaker)
Element Hot surface igniter
Includes Igniter + wiring harness/connector kit
Fit OEM Direct Replacement

Compatibility

Fits ICP, Tempstar, Heil, and Comfortmaker gas furnaces including model RGS121STAB0AAAA. Confirm the igniter mounting tab and connector style against your existing part before installing. Handle the new element by the ceramic base only — never touch the silicon-carbide tip.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position, mounting tab, and harness routing before removal.
  4. Remove — Unplug the harness, remove the igniter mounting screw, and carefully withdraw the cracked element.
  5. Install — Mount the new igniter (handling by the base only), route and connect the new wiring harness per your photo.
  6. Test — Restore power and confirm the igniter glows and lights the burners promptly on a heat call.

Signs You Need a Replacement

  • No heat — burners never ignite on a call
  • Igniter does not glow, or glows weakly
  • Repeated ignition retries followed by lockout
  • Visible crack in the element or melted/chafed harness

Shipping & Returns

Ships same day for orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121STAB0AAAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121STAB0AAAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121STAB0AAAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.