Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS121SRCB0AAA — Igniter + Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS121SRCB0AAA — Igniter + Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface ignition kit for the ICP / Tempstar / Heil RGS121SRCB0AAA gas furnace, including the hot surface igniter (part number 1171306) and the matching igniter wiring kit/harness (part number 1188370). The hot surface igniter glows red-hot on a call for heat to ignite the burner gas; it is one of the most common furnace failure points because the element is brittle and degrades with every heating cycle. The included wiring kit ensures a clean, correct electrical connection and replaces brittle or heat-damaged leads. When the igniter cracks or the element opens, the furnace will not light — you may hear the gas valve and inducer cycle with no ignition, or see a lockout fault. This complete kit restores reliable ignition with the exact OEM components.

Specifications

Spec Value
Part Number (Igniter) 1171306
Part Number (Wiring Kit) 1188370
Type Hot Surface Igniter Kit
Brand ICP / Tempstar / Heil
Includes Igniter + Wiring Harness
Fits Model RGS121SRCB0AAA

Compatibility

Engineered for the ICP-family RGS121SRCB0AAA and shared across many Tempstar, Heil, Comfortmaker, and ICP gas furnaces using this hot surface igniter platform. Confirm the igniter and harness part numbers against your existing parts before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the burner/service panel to reach the igniter at the burner assembly.
  3. Document — Photograph the igniter position and harness routing before disconnecting.
  4. Remove — Unplug the igniter harness and carefully unscrew the brittle old igniter — handle by the ceramic base only.
  5. Install — Mount the new igniter without touching the element, then connect the new wiring kit.
  6. Test — Restore power, start a heat call, and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace will not light — no glow at the igniter
  • Inducer and gas valve cycle with no ignition
  • Visible cracks or breaks in the igniter element
  • Furnace locks out after several failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121SRCB0AAA — Igniter + Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121SRCB0AAA — Igniter + Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121SRCB0AAA — Igniter + Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online