This OEM hot surface igniter kit for the ICP / Tempstar / Heil RGS121SRAB0AAAA gas furnace includes the igniter (part 1171306) and the matched igniter wiring kit (part 1188370). The hot surface igniter glows when 120V is applied at the start of each heat cycle, igniting the burners as the gas valve opens. Because the element is brittle silicon carbide or nitride, it is the single most common cause of intermittent no-heat calls — it cracks from thermal cycling, contamination from oily fingerprints, or simple age. The included wiring kit ensures clean, factory-correct connections so the new igniter receives full voltage. Replacing both together restores reliable ignition and eliminates the repeated lockouts that come from a weak or cracked element.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil / Comfortmaker)
Operating Voltage 120 VAC
Includes Igniter + Wiring Harness Kit
Fitment OEM

Compatibility

Direct factory replacement for the ICP RGS121SRAB0AAAA and compatible Tempstar, Heil, and Comfortmaker gas furnaces that use this hot surface igniter and harness. Verify your furnace model and existing igniter style before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect furnace power, then verify zero voltage at the igniter leads with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter mounting and harness routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter without touching the new element with bare hands.
  5. Install — Mount the new igniter, route and connect the included wiring kit, and confirm the element sits correctly over the burner.
  6. Test — Restore gas and power, start a heat cycle, and verify the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace blower runs but the burners never ignite (no heat).
  • Visible crack or break in the igniter element.
  • Igniter glows weakly or not at all on a call for heat.
  • Repeated ignition lockouts or short-cycling on heat.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121SRAB0AAAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121SRAB0AAAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121SRAB0AAAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online