Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS121SFAB0AAAA — with Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS121SFAB0AAAA — with Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface igniter kit for the ICP / Tempstar / Heil RGS121SFAB0AAAA gas furnace, including the igniter (part 1171306) and its matched wiring kit (part 1188370). On a call for heat, the control board sends line voltage to the igniter, which glows white-hot and lights the burners as gas is introduced. Hot surface igniters are a high-wear consumable: the element is brittle and slowly erodes with every heating cycle until it cracks and can no longer reach ignition temperature. The included wiring kit ensures a clean, correctly terminated connection — important because a corroded or loose igniter plug is a common cause of intermittent no-heat calls. Replacing both together restores reliable first-try ignition.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Element Silicon carbide / silicon nitride style
Includes Igniter + matched wiring harness
Application Gas furnace burner ignition

Compatibility

Designed for the ICP-family RGS121SFAB0AAAA and related Tempstar, Heil, and Comfortmaker gas furnaces using this hot surface ignition system. Confirm the mounting tab and connector match your existing igniter before installing — and never touch the element with bare fingers, as skin oils shorten its life.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power; verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photo the igniter's position, bracket, and harness routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and carefully withdraw the brittle igniter without bumping it.
  5. Install — Seat the new igniter in the same position (handling only the ceramic base), secure the screw, and connect the new wiring kit.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and burners light cleanly within the normal ignition sequence.

Signs You Need a Replacement

  • Furnace clicks and calls for heat but burners never light
  • Igniter no longer glows or glows weakly/unevenly
  • Visible cracks, blistering, or hot spots on the element
  • Intermittent no-heat lockouts that clear on reset

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121SFAB0AAAA — with Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121SFAB0AAAA — with Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121SFAB0AAAA — with Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online