Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS121LEBA0AAAA — OEM with Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS121LEBA0AAAA — OEM with Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit for the ICP/Tempstar/Heil RGS121LEBA0AAAA includes the genuine igniter (part 1171306) and the matching igniter wiring kit (part 1188370). On each call for heat, the control board energizes the igniter, which glows red-hot to light the burner gas. Hot surface igniters are fragile and wear out — they crack, develop hairline fractures, or simply burn out after thousands of cycles. The most common furnace no-heat complaint is an igniter that no longer glows or that glows but won't ignite the burners. The included wiring kit ensures a clean, corrosion-free connection so the new igniter performs reliably.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Includes Igniter element + wiring harness
Fitment OEM — direct replacement

Compatibility

Built for the ICP/Tempstar/Heil RGS121LEBA0AAAA gas furnace and related Carrier-built ICP models using this hot surface igniter and connector. Match the igniter mounting bracket and connector style to your existing part before installing.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off the gas; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment door.
  3. Document — Photograph the igniter position and wiring routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift out the old igniter — handle only by the ceramic base, never the element.
  5. Install — Mount the new igniter without touching the silicon-carbide element, then connect the new wiring kit per your photo.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and lights the burners smoothly.

Signs You Need a Replacement

  • Furnace blower runs but produces no heat
  • Igniter does not glow on a heat call
  • Igniter glows but burners fail to light
  • Visible cracks, white spots, or fractures on the element

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121LEBA0AAAA — OEM with Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121LEBA0AAAA — OEM with Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121LEBA0AAAA — OEM with Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online