Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS121LEAB0AAAA – With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS121LEAB0AAAA – With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter (part #1171306) with matching igniter wiring kit (part #1188370) is the ignition source for the ICP / Heil / Tempstar RGS121LEAB0AAAA gas furnace. On a call for heat, the control board sends voltage to the igniter, which glows white-hot to light the gas at the burners. Hot surface igniters are brittle and degrade over time from thermal cycling and contamination, eventually cracking or failing to reach ignition temperature. The included wiring kit ensures a clean, secure connection and is the recommended replacement whenever the igniter is changed.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP (Heil / Tempstar)
Fits Model RGS121LEAB0AAAA
Fit OEM exact-fit

Compatibility

Designed for the ICP RGS121LEAB0AAAA gas furnace and related ICP-family (Heil, Tempstar, Comfortmaker) furnaces using igniter #1171306. Always confirm the igniter and wiring kit part numbers against your unit's parts list before ordering.

Installation Guide

  1. Safety First – Disconnect power to the furnace and shut off the gas. Verify zero voltage with a multimeter.
  2. Access – Remove the burner compartment door.
  3. Document – Photograph the igniter mounting position and wiring before removal. Handle the igniter only by its ceramic base, never the fragile element.
  4. Remove – Disconnect the igniter harness, remove the mounting screw(s), and carefully withdraw the old igniter.
  5. Install – Mount the new igniter in the same position, install the new wiring kit, and connect per your photos. Do not touch the glowing element with bare fingers.
  6. Test – Restore gas and power, then run a heat cycle and confirm the igniter glows and lights the burners reliably.

Signs You Need a Replacement

  • No glow on a call for heat
  • Visible cracks or breaks in the igniter element
  • Furnace locks out after several failed ignition attempts
  • Delayed ignition or intermittent no-heat starts

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121LEAB0AAAA – With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121LEAB0AAAA – With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121LEAB0AAAA – With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.