Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS121LEAA0AAAA — with Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS121LEAA0AAAA — with Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (Part Number 1171306) with its matched wiring kit (Part Number 1188370) is the ignition source for the ICP / Tempstar / Heil RGS121LEAA0AAAA gas furnace. On a call for heat, the control board sends 120V to the igniter, which glows red-hot and lights the burner gas. Hot surface igniters are brittle silicon-carbide or silicon-nitride elements that degrade with every cycle and eventually crack or lose conductivity. Typical failure symptoms include no heat with the blower still running, the igniter not glowing, repeated lockouts after several ignition attempts, or a hairline crack visible in the element. The included wiring kit ensures a clean, correct electrical connection and proper strain relief.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Operating Voltage 120V
Fitment OEM Replacement

Compatibility

Built for the ICP / Tempstar / Heil RGS121LEAA0AAAA gas furnace. The igniter and wiring kit are sold together so you replace the element and its harness as a complete service set.

Installation Guide

  1. Safety First — Turn off the furnace at the switch and breaker and shut the gas; verify zero voltage with a multimeter.
  2. Access — Remove the burner/control compartment door.
  3. Document — Photograph the igniter mounting and harness routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift out the old igniter. Never touch the new element's surface with bare fingers.
  5. Install — Mount the new igniter, connect the supplied wiring kit, and confirm proper position over the burner.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • No heat although the blower and inducer still run
  • Igniter does not glow on a call for heat
  • Furnace locks out after multiple failed ignition attempts
  • Visible crack, chip, or break in the igniter element

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121LEAA0AAAA — with Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121LEAA0AAAA — with Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121LEAA0AAAA — with Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online