This OEM hot surface igniter (factory part 1171306), supplied with its matching wiring kit (1188370), ignites the burners on the ICP/Tempstar/Heil RGS121LDAA0AAAA gas furnace. On a call for heat, the control board energizes the igniter, which glows to roughly 1,800–2,500°F and lights the gas as it flows across the burners. Igniters are brittle silicon-carbide or silicon-nitride elements that crack from age, thermal cycling, vibration, or handling. A failed igniter is one of the most common no-heat causes: the inducer and gas valve sequence normally but the burners never light, often ending in ignition lockout. The included wiring kit ensures a clean, correctly terminated connection to the harness.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Fits Model RGS121LDAA0AAAA
Includes Igniter + Wiring Kit

Compatibility

Direct-fit replacement for the ICP/Tempstar/Heil/Comfortmaker RGS121LDAA0AAAA and related RGS-series gas furnaces using this hot surface igniter. Confirm the igniter and connector style against your existing part before installing.

Installation Guide

  1. Safety First — Turn off gas and disconnect power; verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter mounting and wiring routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw(s), and withdraw the old igniter without touching the new element with bare fingers.
  5. Install — Mount the new igniter in the correct position, connect using the supplied wiring kit, and route the harness clear of hot surfaces.
  6. Test — Restore gas and power and watch a full ignition cycle: igniter glows, burners light, flame proves.

Signs You Need a Replacement

  • No heat — burners never light despite a normal startup sequence.
  • Visible crack, chip, or break in the igniter element.
  • Furnace locks out after several failed ignition attempts.
  • Igniter no longer glows when energized.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121LDAA0AAAA — OEM 1171306 with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121LDAA0AAAA — OEM 1171306 with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121LDAA0AAAA — OEM 1171306 with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online