Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS121HTAB0AAAA — OEM 1171306 with Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS121HTAB0AAAA — OEM 1171306 with Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter assembly is the direct-fit ignition component for the ICP / Heil / Tempstar RGS121HTAB0AAAA gas furnace. The kit includes OEM ignitor part number 1171306 plus the matching igniter wiring kit 1188370, so you replace the element and its harness together for a clean, reliable repair. The hot surface igniter glows red-hot on each call for heat to ignite gas at the burners. Its brittle ceramic element is among the most common furnace failure points — thermal cycling, soot accumulation, and rough handling cause hairline cracks that break the heating cycle. Common symptoms include the blower running with no heat, repeated ignition attempts ending in lockout, an igniter that never glows, or short-cycling on a hard restart.

Specifications

Spec Value
Part Number (Igniter) 1171306
Part Number (Wiring Kit) 1188370
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Application Gas Furnace Ignition
Fitment OEM Direct Replacement

Compatibility

Engineered as a direct OEM replacement for the ICP / Heil / Tempstar / Comfortmaker RGS121HTAB0AAAA furnace. The included wiring kit allows a plug-and-play connection without splicing the existing harness. Always confirm your model and serial tag before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the lower service panel to expose the burner assembly.
  3. Document — Photograph the igniter bracket position and wiring routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift the old igniter clear — handle only by the ceramic base, never the element.
  5. Install — Mount the new igniter at the same depth and angle, secure the screw, and connect the new wiring kit per your photo.
  6. Test — Restore power, initiate a heat call, and confirm the igniter glows and the burners light within seconds.

Signs You Need a Replacement

  • Igniter no longer glows on a call for heat.
  • Furnace locks out after repeated failed ignition attempts.
  • Visible cracks, blistering, or white spots on the element.
  • Blower runs but the system delivers no warm air.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121HTAB0AAAA — OEM 1171306 with Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121HTAB0AAAA — OEM 1171306 with Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121HTAB0AAAA — OEM 1171306 with Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online