This OEM hot surface igniter kit for the ICP RGS121HTAA0AAAA includes the igniter (part #1171306) and the matching igniter wiring kit (part #1188370). On each call for heat, the control board sends voltage to the igniter, which glows white-hot and ignites the gas at the burners. Hot surface igniters are brittle and degrade over thousands of heating cycles — the element develops hairline cracks, draws less current, and eventually fails to reach ignition temperature, leaving the furnace blowing cold air or locking out on failed ignition. The included wiring harness ensures a clean, corrosion-free electrical connection. Replacing both together restores fast, dependable ignition.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit Igniter)
Type Hot Surface Igniter
Brand ICP (Heil / Tempstar / Comfortmaker)
Includes Igniter + Wiring Harness Kit
Fit OEM Direct Replacement

Compatibility

Designed for the ICP RGS121HTAA0AAAA gas furnace and compatible ICP-family models (Heil, Tempstar, Comfortmaker) using this hot surface igniter. Confirm the igniter mounting and connector style against your existing part before installation.

Installation Guide

  1. Safety First — Shut off gas and disconnect power. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter position and wiring routing before removing.
  4. Remove — Unplug the igniter harness and unscrew the fragile igniter — handle only by the ceramic base, never the element.
  5. Install — Mount the new igniter without touching the element, then connect the new wiring kit.
  6. Test — Restore gas and power, call for heat, and verify the igniter glows and burners light.

Signs You Need a Replacement

  • Furnace ignites then locks out, or blows cold air
  • Igniter does not glow on a heat call
  • Visible cracks or white spots on the igniter element
  • Repeated ignition-failure fault codes

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121HTAA0AAAA — OEM Igniter & Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121HTAA0AAAA — OEM Igniter & Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121HTAA0AAAA — OEM Igniter & Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online