Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS121HFAA0AAAA — With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS121HFAA0AAAA — With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part 1171306) ignites the gas burners on the ICP/Tempstar/Heil RGS121HFAA0AAAA gas furnace, and ships with the matching igniter wiring kit (part 1188370) for a clean, complete replacement. On each call for heat the control board sends 120 volts to the igniter, which glows white-hot to ignite the burner gas. Because the element is brittle silicon carbide or silicon nitride, it is the single most common heating failure in a modern furnace — it can crack from thermal cycling, vibration, or even being touched with bare fingers during a prior repair. A cracked or worn igniter is the usual cause of a furnace that clicks and tries to light but never produces heat. The included wiring kit replaces brittle, heat-aged leads and connectors so the new igniter gets a solid connection.

Specifications

Spec Value
Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Voltage 120 VAC
Kit Contents Igniter plus wiring harness

Compatibility

Direct OEM replacement for the ICP, Heil, Tempstar, and Comfortmaker RGS121HFAA0AAAA gas furnace. Always handle the new igniter by the ceramic base only — never touch the element.

Installation Guide

  1. Safety First — Turn off the gas and disconnect electrical power, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter mounting position and the wiring connection before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter without forcing it.
  5. Install — Set the new igniter so the element sits in the burner flame path, secure the screw, and connect the new wiring kit handling the element only by its base.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace clicks and attempts ignition but never lights.
  • No visible glow in the burner area on a call for heat.
  • Igniter element is visibly cracked, split, or blistered.
  • Intermittent heating or repeated ignition lockouts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121HFAA0AAAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121HFAA0AAAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121HFAA0AAAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online