Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS120SRAB0AAA — OEM 1171306 w/ Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS120SRAB0AAA — OEM 1171306 w/ Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM Hot Surface Igniter (Part #1171306) bundled with the matching Igniter Wiring Kit (Part #1188370) is the ignition source for the ICP / Tempstar / Heil RGS120SRAB0AAA gas furnace. On each heat call, the control board sends voltage to the igniter, which glows white-hot to light the burners. Hot surface igniters are brittle and degrade with every thermal cycle — eventually cracking, developing hairline fractures, or simply failing to reach ignition temperature. The result is no heat, repeated ignition-retry lockouts, or delayed ignition with a noticeable burner 'whoomp.' The included wiring kit ensures a clean, corrosion-free electrical connection.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Fits Model RGS120SRAB0AAA
Fit OEM Direct Replacement

Compatibility

Designed for the ICP-family RGS120SRAB0AAA and related Tempstar, Heil, and Comfortmaker furnaces using this hot surface igniter. The included wiring harness kit (1188370) adapts and secures the connection. Verify your model and existing igniter style before ordering.

Installation Guide

  1. Safety First — Disconnect power to the furnace and verify zero voltage with a multimeter. Allow the igniter to cool completely.
  2. Access — Remove the burner compartment door.
  3. Document — Photograph the igniter position, mounting screw, and wiring connector before removal.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and carefully withdraw the old igniter. Handle the new element only by its ceramic base — never touch the silicon-nitride/carbide element.
  5. Install — Mount the new igniter, install the wiring kit, and reconnect the harness.
  6. Test — Restore power, start a heat cycle, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • No heat — burners never ignite
  • Igniter visibly cracked or no longer glowing
  • Repeated ignition lockouts or short cycling on heat
  • Delayed ignition with a loud burner 'boom'

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120SRAB0AAA — OEM 1171306 w/ Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120SRAB0AAA — OEM 1171306 w/ Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120SRAB0AAA — OEM 1171306 w/ Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online