This OEM hot surface igniter (part number 1171306) with its matching igniter wiring kit (1188370) lights the burners on ICP, Tempstar, and Heil gas furnaces. On a heat call, the control board sends line voltage to the igniter, which glows white-hot and ignites the gas as the valve opens. Hot surface igniters are brittle and degrade with every cycle — eventually they crack, develop hot spots, or fail to reach ignition temperature, leaving you with no heat or a furnace that locks out after several trial-for-ignition attempts. The included wiring kit replaces aged, heat-stressed connectors for a clean, reliable installation on model RGS120SFBA0AAA.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Includes Igniter + Wiring Harness Kit
Brand ICP / Tempstar / Heil
Application Gas Furnace Ignition
Fitment OEM Direct Replacement

Compatibility

Designed for the ICP / Tempstar / Heil RGS120SFBA0AAA gas furnace and platform models using this igniter and harness. Verify the igniter style and connector against your existing part before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power. Verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and wiring routing before disconnecting.
  4. Remove — Unplug the igniter harness and unscrew the old igniter. Handle by the ceramic base only — never touch the element.
  5. Install — Mount the new igniter at the correct depth, install the new wiring kit, and confirm the element sits in the burner flame path without touching metal.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and lights the burners on the first try.

Signs You Need a Replacement

  • No heat; furnace locks out after several ignition attempts.
  • Visible cracks or breaks in the igniter element.
  • Igniter glows weakly or not at all.
  • Delayed ignition or burner "puff" on startup.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120SFBA0AAA — with Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120SFBA0AAA — with Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120SFBA0AAA — with Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online