Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS120SECB0AAA — 1171306 Ignitor + Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS120SECB0AAA — 1171306 Ignitor + Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit is the factory replacement ignition component for the ICP / Tempstar / Heil RGS120SECB0AAA gas furnace. The kit pairs the 1171306 igniter element with the 1188370 igniter wiring harness, giving you everything required to restore reliable ignition. The hot surface igniter is energized by the control board on each call for heat; it glows to roughly 2,000°F and ignites the gas at the burner manifold. Because the igniter element is a brittle silicon-carbide component carrying 120V, it is one of the most common furnace failure points. Typical failure symptoms include a furnace that runs the inducer and blower but never lights, a cracked or visibly burned-out igniter, repeated lockouts after several ignition attempts, or no glow at all when you watch through the sight port.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Voltage 120V
Application Gas Furnace Ignition
Fitment OEM Direct Replacement

Compatibility

Engineered as a direct-fit OEM replacement for the ICP / Tempstar / Heil RGS120SECB0AAA furnace and other models in the same International Comfort Products family that specify igniter 1171306. The included 1188370 wiring kit ensures the connector and lead match the furnace harness without splicing. Always confirm your existing part number before ordering.

Installation Guide

  1. Safety First — Shut off the gas, disconnect electrical power at the furnace switch or breaker, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter mounting and wiring routing before disconnecting anything.
  4. Remove — Unplug the igniter connector, remove the igniter mounting screw, and carefully withdraw the old igniter from the burner bracket. Handle only by the ceramic base — never touch the element.
  5. Install — Seat the new 1171306 igniter in the bracket, secure the mounting screw, and connect the new 1188370 harness to the control board, matching your reference photo.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burners light within the normal ignition window.

Signs You Need a Replacement

  • Furnace inducer and blower run but burners never ignite.
  • Igniter shows cracks, blisters, or a burned-through element.
  • No visible glow through the sight port on a call for heat.
  • Furnace locks out after several failed ignition attempts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120SECB0AAA — 1171306 Ignitor + Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120SECB0AAA — 1171306 Ignitor + Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120SECB0AAA — 1171306 Ignitor + Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online