Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS120LTCB0AAA — With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS120LTCB0AAA — With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part 1171306), bundled with the matching igniter wiring kit (part 1188370), is the component that lights the burners in your ICP, Tempstar, and Heil RGS120LTCB0AAA gas furnace. On each heat call the control board sends voltage to the igniter, which glows white-hot and ignites the gas as it leaves the burners. Hot surface igniters are brittle silicon-carbide or silicon-nitride elements that degrade with every heating cycle and eventually crack or lose conductivity. A failed igniter is the single most common cause of "no heat" on a modern furnace — the inducer runs and the gas valve tries to open, but without ignition the board locks out on a failed-ignition fault. The included wiring kit ensures a clean, correct electrical connection and replaces brittle or heat-damaged leads at the same time.

Specifications

Spec Value
OEM Igniter Part 1171306
OEM Wiring Kit 1188370
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Includes Igniter + Wiring Harness Kit
Fitment OEM Direct Replacement

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil RGS120LTCB0AAA gas furnace. The 1171306 igniter and 1188370 wiring kit are shared across numerous ICP-family condensing and mid-efficiency furnaces — verify the part numbers and the igniter mounting style before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the switch or breaker; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment door to expose the burner assembly and igniter.
  3. Document — Photograph the igniter position and wiring routing before removal.
  4. Remove — Unplug the igniter lead, remove the mounting screw, and lift the old igniter out. Handle only by the ceramic base — never touch the element.
  5. Install — Seat the new igniter at the correct position over the burner, secure the screw, and connect the new wiring kit per your photo.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace blows cold air — no flame on a heat call
  • Igniter does not glow, or glows weakly
  • Control board locks out on a failed-ignition / ignition-lockout code
  • Visible cracks, hot spots, or whitish wear on the igniter element

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120LTCB0AAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120LTCB0AAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120LTCB0AAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online