Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS120LTCA0AAA — With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS120LTCA0AAA — With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter (part number 1171306) with the matching igniter wiring kit (part number 1188370) is the factory ignition source for the ICP / Tempstar / Heil RGS120LTCA0AAA gas furnace. On each call for heat the control board sends voltage to the igniter, which glows red-hot to light the burners. Hot surface igniters are brittle and degrade with every heating cycle until the element finally cracks or fails. The most common no-heat furnace failure is a dead igniter — the inducer runs and the gas valve waits, but the burners never light. The included wiring kit ensures a clean, correct connection without splicing brittle factory leads.

Specifications

Spec Value
Part Number 1171306 (igniter)
Wiring Kit 1188370
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil / Comfortmaker)
Fits Model RGS120LTCA0AAA
Application Gas furnace burner ignition

Compatibility

Direct OEM fit for the ICP RGS120LTCA0AAA and the shared Tempstar, Heil, and Comfortmaker furnace platform. The kit supplies both the igniter element and its dedicated wiring harness.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off gas. Verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter mounting position and harness routing before disconnecting.
  4. Remove — Unplug the igniter lead, unfasten the mounting screw, and withdraw the fragile element without touching the ceramic.
  5. Install — Mount the new igniter (handle only by its base), connect the supplied wiring kit, and route the harness clear of hot surfaces.
  6. Test — Restore gas and power, call for heat, and watch the igniter glow and the burners light within seconds.

Signs You Need a Replacement

  • No heat — inducer runs but burners never ignite
  • Igniter no longer glows or glows weakly
  • Visible crack, blister, or white spot on the element
  • Furnace lockout after several failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120LTCA0AAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120LTCA0AAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120LTCA0AAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online