Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS120LFCA0AAA — 120V Silicon Carbide | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS120LFCA0AAA — 120V Silicon Carbide | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit (part 1171306, with wiring kit 1188370) is the ignition source for the ICP/Tempstar/Heil RGS120LFCA0AAA gas furnace. When the thermostat calls for heat, the furnace control board energizes this 120V silicon carbide igniter, which glows orange-hot and ignites the gas at the burners. The included wiring kit ensures a clean, OEM-spec connection to the control board. A failed igniter is the single most common cause of no-heat calls: the element becomes brittle with each heating cycle and eventually cracks, breaking the circuit so the burners never light.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Element Silicon Carbide
Voltage 120V
Fit OEM Direct Replacement

Compatibility

Engineered for the ICP family RGS120LFCA0AAA gas furnace and shared platform models sold under the Tempstar, Heil, Comfortmaker, and Day & Night brands. Always confirm your model and serial against the unit rating plate before ordering.

Installation Guide

  1. Safety First — Switch off the furnace at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the lower service/burner panel.
  3. Document — Photograph the igniter bracket and wiring connector before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift the old igniter out by its ceramic base — never touch the element.
  5. Install — Seat the new igniter so the element aligns with the burner ports, secure the screw, and connect the new wiring kit per your photo.
  6. Test — Restore power, run a heat cycle, and confirm the igniter glows and the burners light within seconds.

Signs You Need a Replacement

  • Furnace clicks and tries to start but never lights the burners
  • Igniter shows visible cracks, blistering, or no orange glow
  • Repeated short-cycling or lockout after a few ignition attempts
  • Continuity/ohm test on the element reads open

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120LFCA0AAA — 120V Silicon Carbide | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120LFCA0AAA — 120V Silicon Carbide | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120LFCA0AAA — 120V Silicon Carbide | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online