Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS120LFAB0AAA — With Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS120LFAB0AAA — With Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter kit for the ICP/Tempstar/Heil RGS120LFAB0AAA gas furnace includes the igniter (part 1171306) and the matching igniter wiring kit (part 1188370). On each call for heat, the control board sends line voltage to the igniter, which glows red-hot and ignites the gas at the burners. Hot surface igniters are brittle and degrade with every cycle, making them one of the most frequently replaced furnace parts. The included wiring kit ensures a clean electrical connection and is the recommended replacement when the original harness connector is heat-damaged or brittle. Classic failure symptoms include a furnace that runs the inducer and clicks but never lights, a visibly cracked or broken igniter element, an igniter that no longer glows, and short-cycling on ignition lockout. Replacing the igniter and wiring together restores reliable, fast ignition.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Includes Igniter + wiring harness kit
Function Ignites burners on a call for heat
Fitment OEM direct replacement

Compatibility

Built for the ICP RGS120LFAB0AAA gas furnace and related Tempstar, Heil, Comfortmaker, and ICP units using this hot surface igniter and connector. Confirm igniter mounting and connector style before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker and verify zero voltage with a multimeter before touching the igniter.
  2. Access — Remove the burner/service panel to reach the igniter at the burner assembly.
  3. Document — Photograph the igniter position and wiring connector before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and carefully lift out the old igniter (handle by the ceramic base, never the element).
  5. Install — Mount the new igniter without touching the element, then connect it using the new wiring kit per your photo.
  6. Test — Restore power, start a heat cycle, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Inducer runs and board clicks but burners never light
  • Cracked, chipped, or broken igniter element
  • Igniter no longer glows on a call for heat
  • Furnace short-cycles or locks out on ignition failure

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120LFAB0AAA — With Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120LFAB0AAA — With Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120LFAB0AAA — With Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online