This OEM igniter kit for the ICP / Tempstar / Heil RGS120LDBA0AAA furnace includes the hot surface igniter (part 1171306) and the matching igniter wiring kit (part 1188370). On a call for heat, the control board energizes the igniter, which glows red-hot to light the burners before the gas valve opens. Hot surface igniters are fragile and degrade with every cycle — the silicon-carbide or silicon-nitride element eventually cracks or thins until it can no longer reach ignition temperature, producing a no-heat / no-ignition fault. The included wiring kit ensures a clean, correct connection and avoids reusing a brittle, heat-damaged harness.
| Spec | Value |
|---|---|
| Igniter Part Number | 1171306 |
| Wiring Kit Part Number | 1188370 |
| Type | Hot Surface Igniter + Wiring Kit |
| Brand | ICP / Tempstar / Heil |
| Function | Burner ignition |
| Fitment | RGS120LDBA0AAA |
Designed for the ICP-family RGS120LDBA0AAA furnace and shared across many Tempstar, Heil, and Comfortmaker gas furnaces using this hot surface igniter. Confirm the mounting and connector match your existing igniter before ordering.