Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS120LDAA0AKAA — With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS120LDAA0AKAA — With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (Part No. 1171306) with its matching wiring kit (Part No. 1188370) is what lights the burners in your ICP RGS120LDAA0AKAA gas furnace. On a call for heat, the control board sends voltage to the igniter, which glows white-hot and ignites the gas as it leaves the burner manifold. Hot surface igniters are brittle and degrade over thousands of cycles — they are the single most common cause of furnace no-heat. Typical failure signs are a furnace that clicks and tries to start but never lights, a glowing igniter that cracks, or a unit that locks out after several failed ignition attempts. Replacing the igniter with the wiring kit ensures a clean electrical connection and avoids reusing a heat-fatigued plug.

Specifications

Spec Value
Part Number (Igniter) 1171306
Part Number (Wiring Kit) 1188370
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Application Gas Furnace Ignition
Fitment OEM

Compatibility

Fits the ICP/Tempstar/Heil RGS120LDAA0AKAA and related RGS120 gas furnace models using this hot surface igniter assembly. Verify the igniter and connector match your existing part before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/service panel to reach the igniter.
  3. Document — Photograph the igniter mounting position and wiring routing before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw; handle the old igniter by its ceramic base only.
  5. Install — Mount the new igniter without touching the hot surface element, then connect the new wiring kit.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and burners light promptly.

Signs You Need a Replacement

  • Furnace clicks/attempts ignition but burners never light
  • Visible crack or break in the igniter element
  • Igniter does not glow on a call for heat
  • Furnace locks out after repeated failed ignition tries

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120LDAA0AKAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120LDAA0AKAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120LDAA0AKAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online