This OEM hot surface igniter (ICP part #1171306) with matching wiring kit (#1188370) is the component that lights the burners in your ICP / Heil / Tempstar RGS120LDAA0AAA gas furnace. On a call for heat, the control board sends voltage to the igniter, which glows orange-hot to ignite gas at the burner. Igniters are a wear item — repeated heating and cooling cycles make the brittle silicon-nitride or carbide element crack and fail. The included wiring harness kit replaces the heat-fatigued connector and leads that are a frequent secondary failure point. When the igniter fails, the furnace draft inducer and gas valve may sequence normally, but the burners never light and the unit locks out — leaving you with no heat.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP (Heil / Tempstar)
Includes Igniter element + wiring harness kit
Application Gas Furnace Burner Ignition

Compatibility

Direct OEM fit for the ICP / Heil / Tempstar RGS120LDAA0AAA gas furnace. The bundled wiring kit ensures the connector and leads match the furnace harness, avoiding the splice failures common with universal igniters. Verify the mounting bracket orientation against your existing igniter before installing.

Installation Guide

  1. Safety First — Turn off gas and disconnect electrical power; verify zero voltage at the igniter leads with a multimeter.
  2. Access — Remove the furnace burner-compartment door.
  3. Document — Photograph the igniter position, bracket angle, and wiring routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and carefully withdraw the old igniter without touching the new element with bare fingers.
  5. Install — Mount the new igniter, install the supplied wiring kit, and route leads clear of the burner flame path.
  6. Test — Restore gas and power, call for heat, and watch for a clean glow and reliable burner ignition.

Signs You Need a Replacement

  • Furnace runs the inducer but burners never light (no heat)
  • Visible crack or break in the igniter element
  • Igniter glows weakly or not at all
  • Repeated ignition lockouts after several retry attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120LDAA0AAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120LDAA0AAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120LDAA0AAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.