Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS120HTCB0AAA — OEM 1171306 | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS120HTCB0AAA — OEM 1171306 | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter (part number 1171306), supplied with the matching igniter wiring kit (1188370), fits the ICP/Tempstar/Heil RGS120HTCB0AAA gas furnace. The hot surface igniter is a resistive element that glows red-hot when energized, igniting the gas at the burners at the start of each heating cycle. These igniters are brittle and degrade with every thermal cycle, eventually cracking or losing the ability to reach ignition temperature. A failed igniter is the single most common cause of a furnace that runs the inducer and clicks but never lights. The included wiring kit ensures a clean, correct electrical connection during replacement.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Element High-temperature ceramic / silicon carbide
Includes Igniter + Wiring Harness Kit
Fitment OEM Direct Replacement

Compatibility

Designed for the ICP family model RGS120HTCB0AAA and equivalent ICP, Tempstar, Heil, and Comfortmaker gas furnaces using this hot surface igniter. Match the igniter mounting and connector before installing.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off the gas. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment door.
  3. Document — Photograph the igniter position, bracket, and wiring before removal.
  4. Remove — Unplug the igniter harness and carefully unscrew the cracked igniter without touching the new element with bare fingers.
  5. Install — Mount the new igniter, install the wiring kit, and reconnect the harness. Handle the element by its ceramic base only.
  6. Test — Restore gas and power and watch a full ignition sequence: inducer, glow, gas, and flame proof.

Signs You Need a Replacement

  • Furnace clicks and runs the inducer but never lights
  • Igniter shows visible cracks or no longer glows
  • Intermittent or delayed ignition with rough lightoff
  • Control board lockout after failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120HTCB0AAA — OEM 1171306 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120HTCB0AAA — OEM 1171306 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120HTCB0AAA — OEM 1171306 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online