Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS120HTBB0AAA — with Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS120HTBB0AAA — with Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM kit pairs the ICP/Tempstar/Heil hot surface igniter (part 1171306) with the matching igniter wiring kit (part 1188370) for the RGS120HTBB0AAA gas furnace. The hot surface igniter glows incandescent when energized, igniting the gas at the burner during the heating sequence; the wiring kit provides the correct connector and harness leads to splice the igniter to the furnace harness. Hot surface igniters are fragile and degrade with every heat cycle — the silicon-carbide or silicon-nitride element eventually cracks or loses conductivity, leaving the furnace with a blower and inducer running but no ignition. Including the wiring kit ensures a clean, reliable electrical connection rather than reusing a brittle, heat-aged plug.

Specifications

Spec Value
Igniter Part Number 1171306 (IGNITOR)
Wiring Kit Part Number 1188370 (WIRING KIT IGNITER)
Type Hot surface igniter
Brand ICP (Tempstar / Heil / Comfortmaker)
Application Gas furnace burner ignition
Fit OEM replacement

Compatibility

Direct OEM fit for the ICP/Tempstar/Heil RGS120HTBB0AAA furnace and related ICP-family units that use this hot surface igniter and connector. Match the igniter element style and connector to your existing part before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter mounting position and wire routing.
  4. Remove — Unplug the igniter connector and unscrew the igniter bracket. Handle the new igniter only by its base — never touch the element.
  5. Install — Mount the new igniter, then connect it using the new wiring kit, matching the original routing.
  6. Test — Restore power and run a heat cycle; confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace runs the inducer and blower but never lights (no ignition).
  • Cracked, chipped, or visibly worn igniter element.
  • Igniter that no longer glows when energized.
  • Intermittent ignition or repeated lockouts on a call for heat.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120HTBB0AAA — with Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120HTBB0AAA — with Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120HTBB0AAA — with Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online