Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS120HRBB0AAA — With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS120HRBB0AAA — With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit pairs the igniter (part number 1171306) with its matching wiring harness kit (part number 1188370) for the ICP RGS120HRBB0AAA gas furnace. The hot surface igniter is the heart of your furnace's ignition sequence: when the control board calls for heat, line voltage is sent to the igniter element, which glows red-hot and ignites the gas as it flows across the burners. These silicon-carbide or silicon-nitride elements are brittle and degrade with every heating cycle. A cracked or worn igniter is the single most common reason a furnace fails to light. The included wiring kit ensures a clean, corrosion-free connection so the new element receives full voltage. Typical symptoms of a failing igniter include the furnace clicking and attempting to start but never lighting, a glow that is weak or absent, or the unit locking out after several failed ignition attempts.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Application Gas Furnace Ignition
Fitment OEM Replacement Kit

Compatibility

Designed as a direct OEM fit for the ICP / Tempstar / Heil RGS120HRBB0AAA gas furnace. The included wiring kit adapts the connector for a secure factory-correct installation on this and related ICP-family furnace platforms using the same ignition system.

Installation Guide

  1. Safety First — Shut off the gas and disconnect electrical power to the furnace, then verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the furnace burner-compartment door to reach the igniter and burner assembly.
  3. Document — Photograph the igniter mounting position and wiring routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and carefully withdraw the brittle element without touching the ceramic.
  5. Install — Mount the new igniter so the element sits correctly in the burner flame path, then connect the new wiring kit — handle the element by its base only.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows bright and the burners light on the first cycle.

Signs You Need a Replacement

  • Furnace attempts to start but the burners never ignite.
  • Igniter glows dim, uneven, or not at all.
  • Visible cracks or chips in the igniter element.
  • Furnace locks out after repeated failed ignition attempts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120HRBB0AAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120HRBB0AAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120HRBB0AAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online