Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS120HRBA0AAA — OEM 1171306 | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS120HRBA0AAA — OEM 1171306 | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter (part number 1171306), paired with its igniter wiring kit (part number 1188370), fits the ICP/Tempstar/Heil RGS120HRBA0AAA gas furnace. The hot surface igniter is the element that glows red-hot when energized by the control board, lighting the burners at the start of each heat cycle. Igniters are brittle and degrade over time from repeated thermal cycling; they crack, develop hairline fractures, or simply burn out. The most common failure symptom is no heat with the blower and inducer running but no ignition — often the furnace will try several times and then lock out. A cracked igniter may also glow dimly or unevenly. The included wiring kit ensures clean, OEM-correct connections during replacement.

Specifications

Spec Value
Part Number 1171306 (Igniter)
Included Kit 1188370 (Igniter Wiring Kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Application Gas furnace burner ignition
Fits Model RGS120HRBA0AAA
Fit OEM exact replacement

Compatibility

Designed for the ICP/Tempstar/Heil RGS120HRBA0AAA and platform-shared gas furnaces using the same igniter and harness. Handle the igniter element only by its base — never touch the silicon nitride/carbide tip with bare fingers.

Installation Guide

  1. Safety First — Disconnect power to the furnace. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace front and burner compartment panels.
  3. Document — Photograph the igniter position and wiring routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw(s), and carefully withdraw the old igniter without bumping the burners.
  5. Install — Mount the new 1171306 igniter, install the 1188370 wiring kit, and reconnect — handling only the ceramic base.
  6. Test — Restore power and run a heat cycle; confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • No heat — inducer and blower run but burners never light
  • Furnace attempts ignition then locks out
  • Igniter glows weakly, unevenly, or not at all
  • Visible cracks or breaks in the igniter element

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120HRBA0AAA — OEM 1171306 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120HRBA0AAA — OEM 1171306 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120HRBA0AAA — OEM 1171306 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online