Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS120HFCB0AAA — Silicon Nitride with Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS120HFCB0AAA — Silicon Nitride with Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit replaces the ignition component on the ICP / Tempstar / Heil RGS120HFCB0AAA gas furnace. It bundles the silicon-style hot surface igniter (OEM 1171306) with the matching igniter wiring kit (OEM 1188370) so you have the harness and connector needed for a clean swap. The igniter glows to roughly 1,800–2,500°F on a 120V call for heat to light the burner gas. When it cracks, carbon-fouls, or fails open, the furnace blower may run but you get no flame, repeated ignition lockouts, or a unit that short-cycles on a failed light. Replacing the igniter is the single most common furnace no-heat repair.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Voltage 120V
Fit OEM Replacement
Includes Igniter + wiring harness kit

Compatibility

Engineered for the ICP-family RGS120HFCB0AAA gas furnace and shared platform models sold under the Tempstar, Heil, Comfortmaker, and Arcoaire brands. Always confirm your model and serial before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter and shut off gas.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter bracket and wiring connector before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift the fragile igniter straight out without touching the glow element.
  5. Install — Seat the new igniter in the bracket, install the new wiring kit, and reconnect per your photo. Handle the element by the ceramic base only.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and the burners light within one cycle.

Signs You Need a Replacement

  • Furnace ignites no flame despite blower operation
  • Visible cracks or white/blistered spots on the igniter element
  • Repeated ignition lockouts or short-cycling on startup
  • No glow visible through the inspection port on a heat call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120HFCB0AAA — Silicon Nitride with Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120HFCB0AAA — Silicon Nitride with Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120HFCB0AAA — Silicon Nitride with Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online