Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS120HFAB0AGAA — With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS120HFAB0AGAA — With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM kit pairs the hot surface igniter (part 1171306) with its matching igniter wiring kit (part 1188370) for the ICP / Tempstar / Heil RGS120HFAB0AGAA gas furnace. On each call for heat, the control board energizes the igniter, which glows red-hot to ignite the gas at the burners; the included wiring harness provides the correct connector and leads for a clean OEM-grade connection. Hot surface igniters are brittle and degrade with every heating cycle, eventually cracking or losing the ability to reach ignition temperature. The result is a furnace that goes through its sequence — inducer and gas valve — but never lights, often locking out after several failed attempts. Replacing the igniter (and its wiring) restores dependable ignition.

Specifications

Spec Value
Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Includes Igniter + wiring harness
Function Direct burner ignition

Compatibility

Direct OEM fit for the ICP / Tempstar / Heil RGS120HFAB0AGAA and other ICP-family furnaces specifying igniter 1171306 with wiring kit 1188370. Confirm the part numbers and connector style against your existing igniter before ordering.

Installation Guide

  1. Safety First — Disconnect electrical power, shut off the gas, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter mounting and harness routing before removing anything.
  4. Remove — Unplug the igniter harness and carefully unfasten the brittle old igniter without touching the element.
  5. Install — Mount the new igniter (handle by the ceramic base only, never the element), connect the new wiring kit, and route the harness clear of hot surfaces.
  6. Test — Restore gas and power and confirm the igniter glows and lights the burners on a heat call.

Signs You Need a Replacement

  • Furnace runs its sequence but the burners never light.
  • Igniter does not glow or glows weakly.
  • Visible cracks or breaks in the igniter element.
  • Repeated ignition lockouts after several failed attempts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120HFAB0AGAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120HFAB0AGAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120HFAB0AGAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online