Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS120HEBB0AAA — With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS120HEBB0AAA — With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit for the ICP/Heil/Tempstar RGS120HEBB0AAA gas furnace includes the igniter element (part 1171306) and its dedicated wiring harness/igniter wiring kit (part 1188370). On each call for heat, the control board sends voltage to the igniter, which glows red-hot to light the burner gas. Hot surface igniters are brittle and degrade over thousands of cycles until they crack or fail to reach ignition temperature — the most common cause of no-heat furnace calls. Replacing the igniter with its matching harness restores reliable first-try ignition and avoids hard-start and lockout faults.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP (Heil / Tempstar)
Function Burner ignition on call for heat
Includes Igniter element + wiring harness kit

Compatibility

Engineered for the ICP RGS120HEBB0AAA and related Heil, Tempstar, Comfortmaker, and Carrier-built gas furnaces using this hot surface igniter. Match the igniter mounting bracket and harness connector to your original before installing.

Installation Guide

  1. Safety First — Shut off gas, disconnect power, and verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position and harness routing before disconnecting.
  4. Remove — Unplug the igniter harness and unscrew the old igniter; handle by the base only — never touch the silicon-carbide element.
  5. Install — Mount the new igniter, route and connect the new wiring kit per your photo, keeping the element clear of the burner.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and lights the burners on the first cycle.

Signs You Need a Replacement

  • Furnace blower runs but no heat / no flame
  • Igniter does not glow or glows weakly
  • Visible cracks or breaks in the igniter element
  • Repeated ignition lockouts or short cycling

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120HEBB0AAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120HEBB0AAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120HEBB0AAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online