Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS120HEBA0AGAA — with Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS120HEBA0AGAA — with Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit for the ICP / Tempstar / Heil RGS120HEBA0AGAA furnace includes the igniter (part 1171306) and the matching igniter wiring kit (part 1188370). On each call for heat the furnace control board energizes the igniter, which glows red-hot to ignite the burner gas. The included wiring kit ensures a clean, correct electrical connection and proper strain relief between the igniter and the harness. Hot surface igniters are fragile and degrade with every heating cycle — the silicon carbide or nitride element becomes brittle and eventually cracks, at which point the furnace will not light. Replacing the igniter together with fresh wiring eliminates the most common no-heat cause and avoids repeat failures from a worn connector.

Specifications

Spec Value
Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Includes Igniter + Wiring Harness Kit
Fitment OEM Replacement

Compatibility

Designed for the ICP / Tempstar / Heil RGS120HEBA0AGAA furnace and ICP-family furnaces using the same hot surface igniter and connector. Verify part numbers 1171306 / 1188370 and igniter mounting style against your existing unit before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter. Never touch the igniter element with bare fingers.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position, bracket, and wiring routing before removal.
  4. Remove — Unplug the igniter connector and unscrew the old igniter, handling it only by the ceramic base.
  5. Install — Mount the new igniter (touching only the base), then connect the new wiring kit and route it clear of hot surfaces.
  6. Test — Restore power and start a heating cycle; confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace clicks and tries to ignite but burners never light
  • Igniter does not glow, or glows weakly
  • Visible crack, chip, or break in the igniter element
  • Repeated ignition lockouts after several failed attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120HEBA0AGAA — with Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120HEBA0AGAA — with Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120HEBA0AGAA — with Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online