Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS120HDCB0AAA — With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS120HDCB0AAA — With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit for the ICP / Tempstar / Heil RGS120HDCB0AAA includes the igniter (part number 1171306) and the matching igniter wiring kit (part number 1188370). The hot surface igniter glows red-hot when energized to ignite the gas at the burners on each heat call. Igniters are a common wear item — the brittle silicon carbide or nitride element degrades with every thermal cycle and eventually cracks or fails open. Symptoms include a furnace that won't light, an igniter that no longer glows, repeated lockouts after several failed ignition attempts, or a visibly cracked or white-spotted element. The included wiring kit ensures a clean, factory-correct electrical connection.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Includes Igniter + Wiring Harness Kit
Fit OEM Direct Replacement

Compatibility

Engineered for the ICP Tempstar Heil RGS120HDCB0AAA gas furnace and related RGS-series models using the same hot surface ignition system. Confirm against your unit's parts list before ordering.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas supply. Verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel to expose the igniter.
  3. Document — Photograph the igniter mounting position and wiring before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and carefully withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter (handle by the ceramic base only), install the new wiring kit, and reconnect per your photo.
  6. Test — Restore gas and power, then verify the igniter glows and lights the burners on a heat call.

Signs You Need a Replacement

  • Furnace will not light or ignite on a heat call
  • Igniter no longer glows when energized
  • Repeated ignition lockouts after several attempts
  • Cracked, chipped, or white-spotted igniter element

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120HDCB0AAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120HDCB0AAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120HDCB0AAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online