This OEM hot surface igniter (part #1171306) with its matched wiring kit (part #1188370) ignites the burners in your ICP Tempstar Heil RGS102SECA0AAA gas furnace. On a call for heat the igniter glows white-hot and lights the gas at the burner. Igniters are brittle and degrade with every heating cycle — they crack, develop hairline fractures, or lose resistance until they no longer reach ignition temperature. The result is no heat, repeated ignition lockouts, or a furnace that cycles on the limit. Installing the genuine igniter plus the included wiring harness ensures a clean electrical connection and reliable startup.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Includes Igniter + Wiring Harness Kit
Fitment OEM Replacement
Application Gas Furnace Burner Ignition

Compatibility

Fits the ICP Tempstar Heil RGS102SECA0AAA and compatible ICP-family gas furnaces using this hot surface igniter assembly. Handle the igniter element by the ceramic base only — never touch the silicon nitride/carbide element.

Installation Guide

  1. Safety First — Disconnect power to the furnace. Verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment access panel.
  3. Document — Photograph the igniter mounting and wiring connector before removal.
  4. Remove — Unplug the igniter harness, remove the mounting screw(s), and carefully withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter, route and connect the included wiring kit, and confirm the element sits correctly over the burner.
  6. Test — Restore power, start a heat call, and verify the igniter glows and lights the burners.

Signs You Need a Replacement

  • No heat with repeated ignition lockouts
  • Igniter does not glow on a call for heat
  • Visible cracks or breaks in the igniter element
  • Furnace short-cycles or trips on the high limit

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102SECA0AAA — OEM 1171306 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102SECA0AAA — OEM 1171306 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102SECA0AAA — OEM 1171306 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.