Overview

This OEM hot surface igniter kit includes the igniter (part 1171306) and its dedicated wiring kit/harness (part 1188370) for ICP, Heil, and Tempstar gas furnaces. The hot surface igniter (HSI) is a resistive element that the control board energizes at the start of each heating cycle; it glows orange-hot and ignites the gas as it leaves the burners. Igniters are a leading cause of no-heat calls because the element is brittle and degrades with every cycle — it eventually cracks, develops hairline fractures, or loses the ability to reach ignition temperature. The included wiring kit ensures a clean, properly terminated connection back to the control board. Handle the new igniter only by its ceramic base; skin oils on the element can shorten its life.

Specifications

Spec Value
Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot surface igniter
Brand ICP / Heil / Tempstar (OEM)
Includes Igniter element + wiring harness/kit
Fit OEM direct replacement

Compatibility

Direct-fit replacement for ICP/Tempstar/Heil model RGS102LTBB0AAA and related RGS-series furnaces using igniter 1171306. Match the igniter mounting and connector against your existing part before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment access panel.
  3. Document — Photograph the igniter position, orientation, and wiring before removing it.
  4. Remove — Unplug the igniter connector, remove the mounting screw(s), and carefully withdraw the old igniter without striking the element.
  5. Install — Mount the new igniter by its ceramic base only, route and connect the new wiring kit, and confirm correct alignment over the burner.
  6. Test — Restore power, start a heating cycle, and verify the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • No heat — burners never ignite on a call
  • Igniter does not glow or glows weakly
  • Visible cracks, white spots, or breaks in the element
  • Furnace locks out after several failed ignition attempts

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102LTBB0AAA — OEM 1171306 w/ Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102LTBB0AAA — OEM 1171306 w/ Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102LTBB0AAA — OEM 1171306 w/ Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.