OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM hot surface igniter kit for the ICP/Heil/Tempstar RGS102LTAB0AAA gas furnace includes the igniter element (Part No. 1171306) and the matched wiring kit (Part No. 1188370). On each call for heat, the furnace control board energizes the igniter, which glows to roughly 2,500°F and lights the gas at the burners. The hot surface igniter is one of the most common furnace failure points because the brittle silicon-carbide or silicon-nitride element degrades with every heating cycle. Symptoms of a failed igniter include no heat, a furnace that clicks and tries to light but never produces flame, a visibly cracked or dark igniter that never glows, or a unit that locks out after several failed ignition attempts. The included wiring kit ensures a clean, correct electrical connection during replacement.
| Spec | Value |
|---|---|
| OEM Part Numbers | 1171306 (Igniter), 1188370 (Wiring Kit) |
| Type | Hot Surface Igniter |
| Brand | ICP / Heil / Tempstar |
| Includes | Igniter element + wiring harness kit |
| Application | Gas Furnace Ignition |
Built as the factory replacement for the ICP/Heil/Tempstar RGS102LTAB0AAA gas furnace. Because hot surface igniters are mounting- and connector-specific, the included wiring kit makes this a complete drop-in service part for the matched model. Verify the igniter mounting bracket and connector against your existing part before installing.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.