Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS102LTAB0AAA — With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS102LTAB0AAA — With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit for the ICP/Heil/Tempstar RGS102LTAB0AAA gas furnace includes the igniter element (Part No. 1171306) and the matched wiring kit (Part No. 1188370). On each call for heat, the furnace control board energizes the igniter, which glows to roughly 2,500°F and lights the gas at the burners. The hot surface igniter is one of the most common furnace failure points because the brittle silicon-carbide or silicon-nitride element degrades with every heating cycle. Symptoms of a failed igniter include no heat, a furnace that clicks and tries to light but never produces flame, a visibly cracked or dark igniter that never glows, or a unit that locks out after several failed ignition attempts. The included wiring kit ensures a clean, correct electrical connection during replacement.

Specifications

Spec Value
OEM Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Includes Igniter element + wiring harness kit
Application Gas Furnace Ignition

Compatibility

Built as the factory replacement for the ICP/Heil/Tempstar RGS102LTAB0AAA gas furnace. Because hot surface igniters are mounting- and connector-specific, the included wiring kit makes this a complete drop-in service part for the matched model. Verify the igniter mounting bracket and connector against your existing part before installing.

Installation Guide

  1. Safety First — Disconnect power to the furnace and verify zero voltage with a multimeter; shut off the gas supply.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter position and its wiring before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw. Handle by the ceramic base only — never touch the glowing element.
  5. Install — Mount the new igniter, install the wiring kit, and seat the connector firmly. Do not touch the element with bare fingers.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and the burners light within the trial period.

Signs You Need a Replacement

  • No heat; furnace tries to light but never ignites.
  • Igniter never glows or glows weakly.
  • Visible cracks, chips, or dark spots on the element.
  • Furnace locks out after repeated failed ignition attempts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102LTAB0AAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102LTAB0AAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102LTAB0AAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.