Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS102LSCB0AAA — With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS102LSCB0AAA — With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit for the ICP / Heil / Tempstar RGS102LSCB0AAA includes the igniter (P/N 1171306) and matching wiring harness kit (P/N 1188370). On a call for heat, the control board energizes the igniter, which glows white-hot to light the gas at the burners. Hot surface igniters are brittle and degrade with every heating cycle — the element develops hairline cracks, carbon buildup, or simply burns out, producing the classic symptom of a furnace that clicks, draws the inducer, but never lights. The included wiring kit ensures clean, correct terminations so the new igniter receives full voltage and seats securely.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Includes Igniter + wiring harness kit
Function Ignites burner gas on call for heat
Fitment OEM exact-fit

Compatibility

Designed for the ICP / Heil / Tempstar / Comfortmaker RGS102LSCB0AAA gas furnace and related RGS-series furnaces using the same hot surface igniter mount and connector. Verify igniter shape and connector before ordering.

Installation Guide

  1. Safety First — Disconnect power and shut off gas; verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position, mounting screw, and wiring routing.
  4. Remove — Unplug the harness, remove the mounting screw, and lift out the old igniter — handle the element only by its ceramic base, never the hot surface.
  5. Install — Mount the new igniter, install the wiring kit, and route the harness clear of hot surfaces. Never touch the igniter element with bare fingers.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace clicks and runs inducer but never lights
  • Visible cracks or breaks in the igniter element
  • No glow on a call for heat
  • Repeated ignition lockout faults

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102LSCB0AAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102LSCB0AAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102LSCB0AAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online