Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS102LSAB0AAA — OEM 1171306 | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS102LSAB0AAA — OEM 1171306 | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part number 1171306) ships with the matching igniter wiring kit (part number 1188370) for the ICP / Tempstar / Heil RGS102LSAB0AAA gas furnace. On each heating call, the control board sends voltage to the igniter, which glows white-hot to ignite the gas at the burners. Hot surface igniters are brittle silicon-carbide or silicon-nitride elements that degrade with every heating cycle and eventually crack or fail to reach ignition temperature. The included wiring kit ensures a clean, correct electrical connection and replaces brittle or heat-damaged factory leads. Common failure symptoms include no ignition, the furnace locking out after several failed attempts, a visibly cracked or chipped igniter element, or an igniter that no longer glows. Replacing both the igniter and its wiring restores reliable, fast ignition.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Fits Model RGS102LSAB0AAA
Fit OEM Replacement

Compatibility

Engineered for the ICP Tempstar Heil RGS102LSAB0AAA furnace and RGS-series models using igniter 1171306 with wiring kit 1188370. Confirm your model and serial number before ordering, and handle the igniter element only by its base.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter position, orientation, and wiring harness routing.
  4. Remove — Disconnect the igniter plug, remove the mounting screw, and carefully withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter, install the new wiring kit, and route and connect the harness per your photo.
  6. Test — Restore gas and power, then run a heating cycle and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace fails to ignite or locks out after retries
  • Igniter no longer glows on a heating call
  • Visible cracks, chips, or hot spots on the element
  • Intermittent or delayed ignition

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102LSAB0AAA — OEM 1171306 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102LSAB0AAA — OEM 1171306 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102LSAB0AAA — OEM 1171306 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online