Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS102LECA0AAA — OEM 1171306 with Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS102LECA0AAA — OEM 1171306 with Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit for the ICP / Tempstar / Heil RGS102LECA0AAA gas furnace includes the igniter (part number 1171306) and the matching igniter wiring kit (part number 1188370). On each heat call the control board sends voltage to the igniter, which glows red-hot to light the burners. Igniters are the most common gas-furnace failure point — the brittle silicon-carbide or silicon-nitride element cracks from thermal cycling, contamination, or being touched by bare hands, and a cracked element will not glow. The included wiring kit ensures a clean, factory-correct electrical connection and eliminates worn or heat-damaged leads. Symptoms of a failed igniter include no heat, the blower running cold, or a visible igniter that never glows during the ignition sequence.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil / Comfortmaker)
Includes Igniter + wiring harness kit
Fits Model RGS102LECA0AAA
Fitment OEM direct replacement

Compatibility

Engineered for the ICP RGS102LECA0AAA gas furnace and its Tempstar, Heil, and Comfortmaker equivalents. The bundled wiring kit matches the OEM connector so no splicing is required.

Installation Guide

  1. Safety First — Disconnect power to the furnace; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and wiring routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the igniter mounting screw, and carefully lift out the old igniter without touching the new element with bare hands.
  5. Install — Mount the new igniter, install the supplied wiring kit, and route the harness clear of hot surfaces.
  6. Test — Restore power, call for heat, and confirm the igniter glows and the burners light on the first attempt.

Signs You Need a Replacement

  • No heat — burners never light
  • Igniter does not glow during the ignition sequence
  • Visible cracks or chips in the igniter element
  • Furnace locks out after several failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102LECA0AAA — OEM 1171306 with Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102LECA0AAA — OEM 1171306 with Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102LECA0AAA — OEM 1171306 with Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online