OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This is the OEM hot surface igniter (part number 1171306) with its matching igniter wiring kit (part number 1188370) for the ICP/Tempstar/Heil RGS102LDAA0AAA gas furnace. On each heat call, the control board sends line voltage to the igniter, which glows red-hot to ignite the gas at the burners. Hot surface igniters are brittle silicon-carbide or nitride elements and are one of the most common furnace failure points — they crack from thermal cycling, contamination from oily fingers, or vibration. The included wiring kit replaces the connector and leads that often degrade alongside the element. A failed igniter is the classic cause of a furnace that runs the inducer and opens the gas valve but never lights, then locks out.
| Spec | Value |
|---|---|
| Part Number | 1171306 (igniter) |
| Included Kit | 1188370 (igniter wiring kit) |
| Type | Hot Surface Igniter |
| Brand | ICP (Tempstar / Heil / Comfortmaker) |
| Fits Model | RGS102LDAA0AAA |
| Fitment | OEM direct replacement |
Designed for the ICP RGS102LDAA0AAA and the shared ICP furnace platforms sold as Tempstar, Heil, and Comfortmaker that use this hot surface igniter and connector. Match the igniter mounting and connector style to your existing part before installing.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.