This is the OEM hot surface igniter (part number 1171306) with its matching igniter wiring kit (part number 1188370) for the ICP/Tempstar/Heil RGS102LDAA0AAA gas furnace. On each heat call, the control board sends line voltage to the igniter, which glows red-hot to ignite the gas at the burners. Hot surface igniters are brittle silicon-carbide or nitride elements and are one of the most common furnace failure points — they crack from thermal cycling, contamination from oily fingers, or vibration. The included wiring kit replaces the connector and leads that often degrade alongside the element. A failed igniter is the classic cause of a furnace that runs the inducer and opens the gas valve but never lights, then locks out.

Specifications

Spec Value
Part Number 1171306 (igniter)
Included Kit 1188370 (igniter wiring kit)
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil / Comfortmaker)
Fits Model RGS102LDAA0AAA
Fitment OEM direct replacement

Compatibility

Designed for the ICP RGS102LDAA0AAA and the shared ICP furnace platforms sold as Tempstar, Heil, and Comfortmaker that use this hot surface igniter and connector. Match the igniter mounting and connector style to your existing part before installing.

Installation Guide

  1. Safety First — Disconnect electrical power and verify zero voltage at the furnace with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position, bracket, and wiring connector before removal.
  4. Remove — Unplug the igniter connector and unfasten the mounting screw. Handle the new element by its ceramic base only — never touch the hot surface element.
  5. Install — Mount the new igniter at the correct depth and angle, then connect it using the supplied wiring kit.
  6. Test — Restore power, start a heat cycle, and confirm the igniter glows and lights the burners on the first try.

Signs You Need a Replacement

  • Furnace runs the inducer and clicks the gas valve but never lights
  • Igniter does not glow, or glows weakly/unevenly
  • Visible crack, blister, or white spot on the igniter element
  • Repeated ignition lockout after several failed light attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102LDAA0AAA — OEM 1171306 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102LDAA0AAA — OEM 1171306 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102LDAA0AAA — OEM 1171306 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online