Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS102HSAA0AAA — With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS102HSAA0AAA — With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit pairs the igniter element (part 1171306) with its matching wiring kit/harness (part 1188370) for ICP / Heil / Tempstar RGS102HSAA0AAA gas furnaces. On every call for heat, the control board energizes the igniter, which glows white-hot and lights the burners; the included wiring kit ensures a clean, correctly terminated connection so the element gets full voltage. Hot surface igniters are brittle and degrade over thousands of heating cycles — the silicon-nitride or silicon-carbide element develops hairline cracks, draws weak current, and eventually fails to glow. When that happens the furnace runs the inducer but never ignites, locks out after several failed attempts, or short-cycles on ignition failure. Replacing the igniter together with fresh wiring restores reliable, fast ignition.

Specifications

Spec Value
OEM Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter Kit
Includes Igniter element + wiring harness
Brand ICP (Heil / Tempstar / Comfortmaker)
Function Ignites burners on call for heat
Application Gas furnace

Compatibility

Designed for the ICP RGS102HSAA0AAA furnace and shared across many Heil, Tempstar, and Comfortmaker ICP-built models using the same hot surface ignition system. Confirm part numbers 1171306 / 1188370 and connector style against your existing igniter before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter; never touch the igniter element with bare fingers, as skin oils shorten its life.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position and harness routing before removal.
  4. Remove — Unplug the connector and unscrew the cracked or worn igniter from its bracket, handling it only by the ceramic base.
  5. Install — Mount the new igniter by its base, route and connect the new wiring kit, and confirm proper clearance to the burner.
  6. Test — Restore power and run a heat cycle; confirm the igniter glows brightly and lights the burners promptly.

Signs You Need a Replacement

  • Furnace inducer runs but burners never light
  • Igniter glows weakly, intermittently, or not at all
  • System locks out on ignition failure or short-cycles
  • Visible cracks or breaks in the igniter element

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102HSAA0AAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102HSAA0AAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102HSAA0AAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online