Overview

This is a genuine OEM hot surface igniter assembly for the ICP/Tempstar/Heil RGS102HRAA0AAA gas furnace. The igniter (OEM part 1171306) is the silicon-carbide or silicon-nitride element that glows red-hot to ignite the gas at the burners on each heating call. This kit also includes the matching igniter wiring kit (OEM part 1188370) so you can replace the harness and connector that commonly fail or corrode alongside the element. A failed igniter is the single most common cause of "no heat" — when the element cracks, ages, or develops hairline fractures, the furnace locks out and will not light.

Specifications

Spec Value
Igniter Part Number 1171306 (IGNITOR)
Wiring Kit Part Number 1188370 (WIRING KIT IGNITER)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Voltage 120V
Fitment OEM

Compatibility

Engineered for the ICP / Tempstar / Heil RGS102HRAA0AAA gas furnace and the broader RGS102 family of single-stage gas furnaces using this igniter platform. Always verify your existing igniter part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, shut off the gas, and verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photo the igniter mounting and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw(s), and lift the old igniter out by its ceramic base — never touch the fragile element.
  5. Install — Mount the new igniter, install the new wiring kit, and reconnect per your photo. Handle the element by the base only.
  6. Test — Restore gas and power, run a heat call, and confirm the igniter glows and the burners light within seconds.

Signs You Need a Replacement

  • Furnace blower runs but there is no flame and no heat.
  • Igniter does not glow or glows weakly/intermittently.
  • Visible cracks, blistering, or white spots on the element.
  • Control board reports an ignition-failure or lockout fault.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102HRAA0AAA — OEM Ignitor + Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102HRAA0AAA — OEM Ignitor + Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102HRAA0AAA — OEM Ignitor + Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online