Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS102HFCA0AAA — OEM 1171306 | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS102HFCA0AAA — OEM 1171306 | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The OEM Hot Surface Igniter Kit (Igniter 1171306 with Wiring Harness Kit 1188370) is the ignition source for your ICP/Tempstar/Heil RGS102HFCA0AAA gas furnace. When the thermostat calls for heat, the furnace control board sends line voltage to the igniter, which glows white-hot to ignite gas at the burners. Hot surface igniters are brittle and degrade over time from thermal cycling and contamination, making them the single most common cause of a furnace that blows cold air or fails to light. This kit includes the matched igniter and its dedicated wiring harness, so you replace both the element and the connector that often becomes heat-damaged — restoring fast, reliable ignition. Never touch the igniter element with bare fingers; skin oils create hot spots that shorten its life.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Includes Igniter element + wiring harness kit
Fitment OEM exact replacement

Compatibility

Built for the ICP, Tempstar, and Heil RGS102HFCA0AAA gas furnace and related RGS-series models using this hot surface igniter and harness. Confirm your model and serial number before ordering. The included wiring kit ensures a clean electrical connection to the furnace control board.

Installation Guide

  1. Safety First — Turn off gas and disconnect electrical power. Verify zero voltage with a multimeter before proceeding.
  2. Access — Remove the burner compartment service panel to expose the igniter near the burners.
  3. Document — Photograph the igniter position, bracket orientation, and harness routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and carefully withdraw the fragile igniter without bumping the burner assembly.
  5. Install — Mount the new igniter (handle by the ceramic base only), install the new wiring harness, and confirm correct alignment over the burner.
  6. Test — Restore gas and power, start a heat call, and verify the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace blows cold air or fails to ignite on a heat call.
  • Igniter does not glow, or shows cracks/breaks in the element.
  • Repeated ignition lockouts or short cycling.
  • Visible heat damage to the igniter connector or wiring.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102HFCA0AAA — OEM 1171306 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102HFCA0AAA — OEM 1171306 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102HFCA0AAA — OEM 1171306 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online