Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS102HECB0AAA — OEM 1171306 with Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS102HECB0AAA — OEM 1171306 with Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part 1171306) with its matching igniter wiring kit (part 1188370) ignites the burners on the ICP Tempstar Heil RGS102HECB0AAA gas furnace. On a heat call, the control board energizes the igniter; it glows white-hot to light the gas at the burner. Hot surface igniters are brittle and degrade with every heat cycle — a hairline crack, oxidation, or contamination from oils and dust causes no-heat lockouts, delayed ignition, or a furnace that runs the inducer and then shuts down on failed ignition. The included wiring kit ensures a clean, properly terminated connection.

Specifications

Spec Value
Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Element Silicon carbide / nitride hot surface
Includes Igniter + wiring harness kit
Fit OEM direct replacement

Compatibility

Designed for the ICP RGS102HECB0AAA and shared-platform Tempstar, Heil, and Comfortmaker gas furnaces that use this hot surface igniter and harness. Confirm the mounting and connector against your existing igniter.

Installation Guide

  1. Safety First — Disconnect furnace power and shut off the gas. Verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment door.
  3. Document — Photograph the igniter position and harness routing before removal.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter — handle only by the ceramic base, never the element.
  5. Install — Mount the new igniter without touching the element, then connect the new wiring kit.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm a clean light-off.

Signs You Need a Replacement

  • Furnace runs the inducer but never lights
  • No glow visible at the igniter on a heat call
  • Delayed ignition or burner "rollout" puff
  • Cracked, blistered, or visibly broken igniter element

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102HECB0AAA — OEM 1171306 with Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102HECB0AAA — OEM 1171306 with Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102HECB0AAA — OEM 1171306 with Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online