Overview

This is the OEM hot surface igniter kit for the ICP / Tempstar / Heil RGS102HEBA0AAA gas furnace, supplied with igniter part number 1171306 and igniter wiring kit 1188370. The hot surface igniter is the component that glows red-hot at the start of each heating cycle to light the gas at the burners. It is one of the most common furnace failure points because the silicon-carbide or silicon-nitride element becomes brittle with thermal cycling and eventually cracks. When the igniter fails, the furnace blower and inducer may run but the burners never light, leaving you with no heat. The included wiring kit lets you replace a brittle, heat-damaged igniter harness at the same time so the new element gets clean, reliable power.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Fits Model RGS102HEBA0AAA
Application Gas Furnace Ignition
Fit OEM Direct Replacement

Compatibility

Designed as a direct-fit replacement for the ICP / Tempstar / Heil RGS102HEBA0AAA furnace. This igniter assembly is used across many ICP-family gas furnaces of this vintage; verify your existing igniter part number (1171306) before ordering for an exact match.

Installation Guide

  1. Safety First – Shut off gas and disconnect electrical power at the furnace switch and breaker. Verify zero voltage with a multimeter.
  2. Access – Remove the furnace burner-compartment service panel.
  3. Document – Photograph the igniter mounting and wiring connection before disconnecting.
  4. Remove – Unplug the igniter harness, remove the mounting screw, and carefully withdraw the old igniter from the burner assembly. Handle only by the ceramic base – never touch the element.
  5. Install – Seat the new igniter in the same position, install the mounting screw, and connect the new wiring kit. Do not let the element contact metal.
  6. Test – Restore gas and power, then start a heat call and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace inducer and blower run but burners never ignite.
  • Igniter shows visible cracks, hot spots, or no longer glows.
  • Repeated ignition lockouts or short-cycling on a heat call.
  • Cracked, melted, or brittle igniter wiring near the burner box.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102HEBA0AAA – Igniter + Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102HEBA0AAA – Igniter + Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102HEBA0AAA – Igniter + Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.