Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS102HDCB0AAA — With Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS102HDCB0AAA — With Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter kit includes the ignitor (part 1171306) and the matching igniter wiring kit (part 1188370) for the ICP / Tempstar / Heil RGS102HDCB0AAA gas furnace. The hot surface igniter is the component that glows red-hot when energized to ignite the gas at the burners on each heat call. Over time the brittle silicon-carbide or nitride element cracks from thermal cycling, develops hairline fractures, or simply burns out — and a failed igniter is one of the most common causes of a furnace that calls for heat but never lights. The included wiring kit ensures a clean, correctly-pinned electrical connection so you replace the harness and igniter together for a reliable repair.

Specifications

Spec Value
Part Number (Igniter) 1171306 — IGNITOR
Part Number (Wiring) 1188370 — WIRING KIT IGNITER
Type Hot surface igniter
Brand ICP / Tempstar / Heil
Includes Igniter + wiring harness kit
Fitment OEM direct replacement
Application Gas furnace burner ignition

Compatibility

Engineered for the ICP/Tempstar/Heil RGS102HDCB0AAA gas furnace and related RGS-series furnaces using this hot surface igniter and harness. Match the igniter element shape and connector before installing. Handle the element only by its ceramic base — never touch the glow element with bare fingers.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment access panel.
  3. Document — Photograph the igniter position, mounting screw, and harness routing.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and carefully withdraw the fragile old igniter.
  5. Install — Mount the new igniter (touching only the ceramic base), connect the new wiring kit, and route the harness clear of hot surfaces.
  6. Test — Restore power, start a heat call, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace calls for heat but burners never ignite
  • Visible cracks, breaks, or white spots on the igniter element
  • Igniter no longer glows when energized
  • Repeated ignition lockouts or short-cycling on heat calls

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102HDCB0AAA — With Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102HDCB0AAA — With Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102HDCB0AAA — With Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online