Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS101SRAA0AAAA — Igniter + Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS101SRAA0AAAA — Igniter + Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine ICP hot surface igniter kit pairs the OEM igniter (part 1171306) with its matching wiring kit (part 1188370) for the ICP / Tempstar / Heil RGS101SRAA0AAAA gas furnace. The hot surface igniter is the element that glows red-hot on a call for heat to light the burners; the included wiring harness ensures a clean, correct electrical connection to the control board. Hot surface igniters are brittle and wear out — they crack from thermal cycling, contamination, or handling, which results in no ignition and a furnace that won't fire. Installing the igniter together with fresh wiring eliminates intermittent connection faults and restores reliable startup.

Specifications

Spec Value
OEM Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot surface igniter with wiring harness
Brand ICP / Tempstar / Heil
Fit OEM exact replacement
Function Ignites burners on a heat call

Compatibility

Designed for the ICP / Tempstar / Heil RGS101SRAA0AAAA and furnaces using the same hot surface igniter and connector. Verify the igniter mounting and plug style match before installing. Handle the igniter element only by its base — skin oils shorten its life.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment panel.
  3. Document — Photograph the igniter position and wiring routing before disconnecting.
  4. Remove — Unplug the harness and unscrew the cracked igniter without touching the new element's surface.
  5. Install — Mount the new igniter, route and connect the new wiring kit to the control board.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace won't ignite or locks out on ignition failure
  • Visibly cracked or broken igniter element
  • Igniter glows weakly or not at all
  • Intermittent no-heat calls from a loose or frayed harness

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101SRAA0AAAA — Igniter + Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101SRAA0AAAA — Igniter + Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101SRAA0AAAA — Igniter + Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online