Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS101SFCA0AAA — With Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS101SFCA0AAA — With Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM kit pairs the hot surface igniter, part number 1171306, with its matching igniter wiring kit, part number 1188370, for ICP / Tempstar / Heil furnace model RGS101SFCA0AAA. The hot surface igniter glows red-hot on a heat call to ignite the gas at the burners. Igniters are brittle and degrade with every cycle, eventually cracking or losing the ability to reach ignition temperature. Including the wiring kit replaces the connector and leads that often become heat-damaged or corroded alongside the igniter. Common symptoms of failure are no ignition, a furnace that clicks and tries to light but produces no flame, or a unit that locks out after several failed attempts.

Specifications

Spec Value
Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot surface igniter + wiring kit
Brand ICP / Tempstar / Heil
Function Burner ignition
Includes Igniter element and replacement wiring/connector
Fitment OEM

Compatibility

Designed for ICP / Tempstar / Heil RGS101SFCA0AAA and related RGS-series furnaces using this hot surface igniter. Confirm the igniter mounting and connector against your original before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power; verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position and wiring routing before removal.
  4. Remove — Unplug the igniter connector, unfasten the mounting screw, and carefully withdraw the fragile element — handle only by the ceramic base, never the hot surface.
  5. Install — Mount the new igniter, route and connect the new wiring kit per your photo, keeping the element clear of the burner.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • No ignition or no flame on a heat call
  • Visible cracks or breaks in the igniter element
  • Igniter glows weakly or not at all
  • Furnace locks out after repeated failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101SFCA0AAA — With Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101SFCA0AAA — With Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101SFCA0AAA — With Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online