This OEM hot surface igniter (part number 1171306) plus matching igniter wiring kit (1188370) is the ignition source for the ICP / Heil / Tempstar RGS101SEBA0AAAA gas furnace. On each heat call, the control board sends voltage to the igniter, which glows white-hot to ignite the gas at the burners. Hot surface igniters are brittle and degrade with every cycle, so they are the single most common cause of furnace no-heat failures. Including the dedicated wiring kit ensures the connector and harness are fresh, eliminating the intermittent connection problems that cause an igniter to glow but not reliably light.
| Spec | Value |
|---|---|
| Part Number | 1171306 (igniter), 1188370 (wiring kit) |
| Type | Hot Surface Igniter |
| Brand | ICP (Heil / Tempstar / Comfortmaker) |
| Includes | Igniter + wiring/connector kit |
| Application | Gas furnace ignition |
| Fit | OEM direct replacement |
Designed for the ICP/Heil/Tempstar RGS101SEBA0AAAA furnace and related RGS-series models using this igniter. Verify the igniter shape, mounting tab, and connector against your original before installing.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.