Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS101LTCB0AAA — with Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS101LTCB0AAA — with Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter (part number 1171306) with matching igniter wiring kit (part number 1188370) replaces the ignition source on the ICP / Tempstar / Heil RGS101LTCB0AAA gas furnace. On each heat call, the control board energizes the igniter; it glows white-hot and lights the gas at the burners. Hot surface igniters are brittle and degrade with every cycle — a hairline crack or eroded element means no ignition and no heat. The included wiring kit ensures a clean, corrosion-free electrical connection, eliminating the intermittent no-heat faults caused by aged or brittle igniter leads.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Fitment OEM exact-fit
Application Gas furnace burner ignition

Compatibility

Designed for the ICP RGS101LTCB0AAA and shared-platform Tempstar, Heil, and Comfortmaker furnaces using this igniter and harness. The wiring kit adapts the new igniter to the existing furnace harness. Verify igniter mounting and connector style against your old part before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and wiring before removal.
  4. Remove — Unplug the igniter lead, remove the mounting screw, and carefully withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter (handle by the ceramic base only), connect the wiring kit, and route leads away from heat.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and lights the burners.

Signs You Need a Replacement

  • No ignition and no heat on a call for heat
  • Visible cracks, chips, or white spots on the igniter element
  • Igniter glows weakly or not at all
  • Furnace locks out after several failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101LTCB0AAA — with Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101LTCB0AAA — with Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101LTCB0AAA — with Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.