Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS101LTCA0AAA — OEM 1171306 | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS101LTCA0AAA — OEM 1171306 | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter (part number 1171306) with its matching wiring kit (part number 1188370) is the ignition source for the ICP / Tempstar / Heil RGS101LTCA0AAA gas furnace. On each call for heat, the furnace control board sends voltage to the igniter, which glows red-hot and lights the gas at the burners. Hot surface igniters are made from a brittle silicon material and are the most common furnace failure point — they degrade with every heating cycle and eventually crack or stop glowing. The included wiring kit ensures a clean, factory-correct electrical connection so the new igniter receives the proper voltage. A no-heat call with the blower running and no flame is almost always a failed igniter.

Specifications

Spec Value
Part Number 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Application Gas Furnace Ignition
Fits Model RGS101LTCA0AAA
Fitment OEM Direct Replacement

Compatibility

Engineered as a direct-fit replacement for the ICP Tempstar Heil RGS101LTCA0AAA. This igniter and wiring kit combination is used across many ICP-built RGS-series gas furnaces and related Tempstar, Heil, Comfortmaker, and Arcoaire models. Verify the igniter's mounting style and connector against your existing part before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power to the furnace. Verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and wiring routing before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw. Handle the old igniter only by its ceramic base — never touch the glowing element area.
  5. Install — Mount the new 1171306 igniter using the supplied 1188370 wiring kit, keeping fingers off the silicon element to avoid contamination.
  6. Test — Restore gas and power, start a heat call, and confirm the igniter glows and lights the burners reliably.

Signs You Need a Replacement

  • Furnace blower runs but burners never ignite (no heat)
  • Igniter does not glow when inspected during a heat call
  • Visible cracks or breaks in the igniter element
  • Furnace locks out after repeated failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101LTCA0AAA — OEM 1171306 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101LTCA0AAA — OEM 1171306 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101LTCA0AAA — OEM 1171306 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online