Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS101LSAB0AAAA — With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS101LSAB0AAAA — With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine ICP/Tempstar/Heil hot surface igniter kit (OEM igniter 1171306 plus wiring harness kit 1188370) is the component that lights the burners on your gas furnace. When the control board calls for heat, line voltage heats the igniter element to a glowing temperature, igniting the gas at the burner. Hot surface igniters are brittle silicon-carbide or silicon-nitride elements that crack from thermal cycling, age, or contact. A failed igniter is one of the most common causes of a no-heat call — the furnace draws air and clicks but never lights. This kit includes the matching wiring harness so the connector and pigtail are replaced together for a clean, reliable install.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Application Gas Furnace Burner Ignition

Compatibility

Direct OEM replacement for ICP Tempstar Heil gas furnace model RGS101LSAB0AAAA. The included wiring kit ensures the harness and connector match the furnace control board. Confirm the part numbers against your existing igniter before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner compartment door.
  3. Document — Photograph the igniter bracket position and wire routing before removal.
  4. Remove — Unplug the igniter harness and unscrew the old igniter, handling it only by its ceramic base — never touch the element.
  5. Install — Mount the new igniter, route and connect the new wiring kit, and confirm proper gap and alignment to the burner.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm the igniter glows and lights the burners.

Signs You Need a Replacement

  • Furnace clicks and runs the inducer but never lights
  • Visible crack or break in the igniter element
  • Igniter no longer glows on a heat call
  • Repeated lockouts after several failed ignition attempts

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101LSAB0AAAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101LSAB0AAAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101LSAB0AAAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online