Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS101LRBB0AAAA — With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS101LRBB0AAAA — With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit for the ICP / Tempstar / Heil RGS101LRBB0AAAA gas furnace includes the igniter element (part 1171306) and a matched wiring kit/harness (part 1188370) for a complete, hassle-free replacement. The hot surface igniter (HSI) is the part that glows red-hot when the furnace calls for heat, lighting the gas at the burners. It is the single most common furnace failure: the brittle silicon-carbide or nitride element degrades with every heat cycle and eventually cracks or burns out, leaving the furnace unable to ignite. Because the included wiring kit replaces the connector and leads that often corrode or melt near the hot element, this kit restores a reliable ignition circuit in one job.

Specifications

Spec Value
Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil / Comfortmaker)
Fits Model RGS101LRBB0AAAA
Includes Igniter element + wiring harness kit
Fitment OEM direct replacement

Compatibility

Engineered as the factory hot surface igniter for the ICP-built RGS101LRBB0AAAA furnace and its Tempstar, Heil, and Comfortmaker badge variants. Handle the new igniter only by its ceramic base — skin oils can create hot spots that shorten its life. Verify the igniter mounting tab and connector against your original.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment door to expose the igniter at the burner.
  3. Document — Photograph the igniter position, mounting screw, and connector before disconnecting.
  4. Remove — Unplug the igniter lead, remove the mounting screw, and carefully withdraw the fragile element.
  5. Install — Seat the new igniter (touching ceramic only), secure the screw, and connect the new wiring harness.
  6. Test — Restore power, call for heat, and confirm the igniter glows and lights the burners promptly.

Signs You Need a Replacement

  • Furnace clicks/calls for heat but burners never light
  • Igniter does not glow or glows weakly
  • Visible crack, blister, or break in the element
  • Repeated ignition lockouts on the control board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101LRBB0AAAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101LRBB0AAAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101LRBB0AAAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online